Descriptive
& Installation Data |
HYPAC
power units can be applied to single acting
cylinders by plugging one port. It will
still be necessary to reverse motor to promote
return flow.
Where solenoid valves are used, wiring circuit
must open valves when motor/pump unit is running,
regardless of direction, to permit free flow of
fluid in system.
Speed of cylinder stroke is dependent on loads
applied at piston rod can be approximated from
performance curves of motor/pump units by
converting G.P.M. to cubic inches per minute.
Motor/pump units assembled complete with
cylinders and inter-connecting hoses can be
supplied to suite individual applications.
Furnish complete details of intended application
with a sketch showing required location of
cylinders in relation to motor/pump for our
recommendations.
Power units assembled complete at our factory are
supplied with proper amount of fluid.
System is purged to eliminate all air pockets and
tested for proper operation.
Where individual motor/pumps are
supplied for customer installation of hoses
and/or cylinders the following procedures are
recommended:
- Use high
grade light industrial white (mineral)
oil or Dextron II Transmission Fluid in
system.
- Place
cylinders in vertical position with
piston rod end up and piston rod fully
retracted. Completely fill piston
end of cylinder with fluid.
Cylinder may be tilted to facilitate
filling.
- Completely
assemble all hose assemblies to
motor/pump and cylinders making sure all
threaded ports have seal ring in
place. All fittings must be firmly
seated in threaded ports.
- Fill
reservoir up to level of fill hole or
approximately 3/4 full if pump is in
vertical position.
- Disconnect,
at pump, retraction hose assembly (which
is attached to piston rod end of
cylinders).
- Plug this
port to completely exclude air.
- Hold the open
hose port at reservoir opening and
actuate pump to extended cylinders until
no air is evident in the fluid
stream. Full extension of rod
should not be necessary.
- Shut off
pump, remove plug, and reconnect hose
assembly to pump port.
- Stand
cylinders on opposite end (rod end down).
- Disconnect,
at pump, extension hose assembly (which
is attached to cylinder at end opposite
piston rod) and follow same procedure as
outlined in notes 6 through 8 except full
retraction is necessary.
- Operate all
cylinders to full extension and
retraction two or three times observing
for evidence of air in system. Air
can be noted by periodic noise in
motor/pump and/or excessive foaming of
fluid in reservoir.
- If air is
evident, recycle cylinders several
times. If this does not eliminate
air, repeat complete procedure making
sure all seals are in place and fittings
are tight.
- Check level
of fluid in reservoir with motor pump in
horizontal position. Level should
be even with fill hole. Assemble
plug with O-ring seal in fill hole.
|